### Basic Numerical Examples Source: https://github.com/taffen/tek-17/blob/main/TEK17.md Simple numerical examples. ```text 2 og flere 2 ``` ```text 6 1 og flere 2 ``` ```text 2 ``` ```text 2 ``` ```text 2 ``` -------------------------------- ### Example Roofing Classification Source: https://github.com/taffen/tek-17/blob/main/TEK17.md Indicates a roofing classification example. ```text ROOF ``` -------------------------------- ### Example Cladding Classification Source: https://github.com/taffen/tek-17/blob/main/TEK17.md Represents a cladding classification example. ```text 2 ``` -------------------------------- ### Example Floor Covering Classifications Source: https://github.com/taffen/tek-17/blob/main/TEK17.md Shows an example of floor covering classification, including smoke production subclasses. ```text ca ca ca ca ``` -------------------------------- ### Example Performance Requirements Source: https://github.com/taffen/tek-17/blob/main/TEK17.md Provides quantitative performance requirements for door dimensions and thermal insulation. ```text 1. Dør internt i byggverk med krav om universell utforming skal ha fri bredde på minimum 0,86 m. 2. Maksimalt tillatt varmetap (U-verdi) for yttervegg er 0,22 [W/mK]. ``` -------------------------------- ### Example Functional Requirements Source: https://github.com/taffen/tek-17/blob/main/TEK17.md Illustrates qualitative functional requirements for building safety and ventilation. ```text 1. Kommunikasjonsveier skal være sikre og brukbare for den ferdsel og transport som forventes. 2. Ventilasjonen skal være tilpasset forurensningsbelastning fra personer. ``` -------------------------------- ### Table Header Example Source: https://github.com/taffen/tek-17/blob/main/TEK17.md This is a header row from a table detailing landslide risk assessment categories and corresponding example measures. ```text Tiltakskategori Forutsetninger og eksempel på type tiltak ``` -------------------------------- ### Example of Fire Resistance Indication Source: https://github.com/taffen/tek-17/blob/main/TEK17.md Illustrates how fire resistance is indicated for building parts, using 'EI 60' as an example, signifying 60 minutes of integrity and insulation. ```text EI 60 ``` -------------------------------- ### Documentation Phases in a Building Project Source: https://context7.com/taffen/tek-17/llms.txt Details the three main phases of documentation in a building project: concept, detailed design, and execution. Each phase has specific documentation requirements and examples. ```plaintext Dokumentasjonsfaser i et byggeprosjekt: 1. KONSEPT (§ 2-2) - Dokumentasjon for oppfyllelse av funksjonskrav - Underlag tilstrekkelig for detaljprosjektering - Eksempel: Brannsikkerhetsstrategi, energikonsept 2. DETALJPROSJEKTERING (§ 2-3) - Dokumentasjon for oppfyllelse av ytelser - Produksjonsunderlag for utførelse - Eksempel: Arbeidstegninger, produktspesifikasjoner 3. UTFØRELSE (§ 2-4) - Dokumentasjon for at utførelsen samsvarer med produksjonsunderlaget - Eksempel: Fuktmålinger, tetthetsmålinger, fotografier av innbygde deler Krav til dokumentasjon: - Skal være skriftlig (inkl. digital) - Skal foreligge på norsk, svensk eller dansk (jf. SAK10 § 5-5) - Skal være etterprøvbar og sporbar Bruk av standarder: - Norsk Standard (NS) eller likeverdig standard kan dokumentere krav og ytelser - Der årstall ikke er angitt: gjeldende versjon legges til grunn - Nasjonale tillegg (NA) til Eurokodene er normative og skal legges til grunn ``` -------------------------------- ### Accessibility for Cleaning and Maintenance of Installations Source: https://github.com/taffen/tek-17/blob/main/TEK17.md This snippet emphasizes the need for safe and accessible features in heating and cooling installations to facilitate easy and efficient cleaning and maintenance, including safe sweeping. It suggests accessible and marked valves for rational execution. ```text Installasjonen bør ha lett tilgjengelige og merkede ventiler på kurser og opplegg for rasjonell utføring av innregulering, vedlikehold og utskifting. ``` -------------------------------- ### Evacuation Time Calculation Example Source: https://github.com/taffen/tek-17/blob/main/TEK17.md This code snippet illustrates a calculation for determining a sufficient evacuation time, setting it to 12 hours based on assumed needs. ```plaintext Evakueringstiden settes til 12 timer da det må antas at dette vil være tilstrekkelig for å evakuere innbyggerne til et tryggere sted i kommunen. ``` -------------------------------- ### Energy-Efficient Pipe Sizing in Heating Systems Source: https://github.com/taffen/tek-17/blob/main/TEK17.md This snippet explains that pipes, fittings, and valves in heating installations should be dimensioned for optimal energy economy by minimizing pressure loss. It emphasizes the goal of energy-efficient operation. ```text Bestemmelsen tilsier at rør, rørdeler, ventiler og liknende dimensjoneres slik at trykktapet blir energiøkonomisk optimalt. ``` -------------------------------- ### Applying Pre-accepted Performance Standards Source: https://github.com/taffen/tek-17/blob/main/TEK17.md Instructs on using pre-accepted performance examples for safety class assessment and how to evaluate buildings not listed by considering consequences of flooding. ```text Når det skal vurderes hvilken sikkerhetsklasse et byggverk skal plasseres i, må de angitte eksemplene i preaksepterte ytelser normalt legges til grunn. For byggverk som ikke er angitt under preaksepterte ytelser, må plasseringen i sikkerhetsklasse vurderes i det enkelte tilfelle ut fra konsekvensene ved oversvømmelse. Dersom byggverket er sammenlignbart med et byggverk angitt under preaksepterte ytelser, må dette inngå i grunnlaget for vurderingen. ``` -------------------------------- ### Choosing Between Pre-accepted Performance Levels Source: https://github.com/taffen/tek-17/blob/main/TEK17.md Explains that project designers can select the most suitable pre-accepted performance levels when multiple options are available. ```text Dersom preaksepterte ytelser gir valgmuligheter, kan ansvarlig prosjekterende velge de ytelsene som er best egnet for prosjektet. ``` -------------------------------- ### Environmental Impact Examples - Nature and Local Environment Source: https://github.com/taffen/tek-17/blob/main/TEK17.md Provides an example of an environmental impact related to protecting valuable or threatened nature in an area during construction. ```text Plante- og dyreliv, landskap ``` ```text Bygging i et område med verdifull eller truet natur som må ivaretas ved særskilte tiltak. ``` -------------------------------- ### Environmental Impact Examples - Air Emissions Source: https://github.com/taffen/tek-17/blob/main/TEK17.md Lists examples of air emissions, including CO2 from fossil fuel heating and particle emissions from wood stoves. ```text Utslipp til luft ``` ```text Utslipp av COfra fossilt brensel til oppvarming ``` ```text Partikkelutslipp fra vedovn ``` -------------------------------- ### Using Pre-accepted Performance Levels Source: https://github.com/taffen/tek-17/blob/main/TEK17.md Describes the implications of using pre-accepted performance levels without deviation and the documentation requirements. ```text Dersom de preaksepterte ytelsene legges til grunn uten fravik, må dette framgå av den dokumentasjonen som utarbeides i prosjektet. Dette er tilstrekkelig til å dokumentere at funksjonskravene i forskriften er oppfylt. ``` -------------------------------- ### Examples of Flood Protection Measures Source: https://github.com/taffen/tek-17/blob/main/TEK17.md Lists examples of risk-reducing measures for flood protection, such as raising the building ground, avoiding basements, or constructing flood walls. ```text Eksempler på sikringstiltak vil være å heve byggegrunnen til flomsikkert nivå, bygge uten kjeller, eller bygge flomvoller eller andre konstruksjoner som holder vannet unna bebyggelsen. ``` -------------------------------- ### Guidance to the Provision Source: https://github.com/taffen/tek-17/blob/main/TEK17.md This section provides general guidance and context for the building technical regulations. ```text Veiledning til bestemmelsen ``` ```text Hovedformålet med forskriften er å bidre til byggverk av god kvalitet som er i samsvar med de krav som er gitt i eller i medhold av plan- og bygningsloven, herunder forskrifter og arealplaner med bestemmelser. Forskriften setter krav til tiltak innenfor viktige områder som visuell kvalitet, universell utforming, sikkerhet mot naturpåkjenning, uteareal, ytre miljø, konstruksjonssikkerhet, sikkerhet ved brann, planløsning, inneklima og helse, og energi. Kravene gjelder for tiltak omfattet av plan- og bygningslovgivningen (pbl § 20-1 ), uavhengig av om arbeidene krever søknad til kommunen eller ikke. ``` ```text Veiledning til bestemmelsen ``` ```text For tiltakene som er beskrevet i denne bestemmelsen gjelder en rekke unntak fra byggteknisk forskrift. Bestemmelsen angir hvilke deler av byggteknisk forskrift som kommer til anvendelse for driftsbygninger i landbruket, og tilsvarende bygninger for husdyr utenom landbruket, fritidsbolig med én boenhet, husvære for seterbruk, reindrift eller skogsdrift, konstruksjoner, anlegg og midlertidige bygninger, bygninger som oppføres som studentbolig, samt bruksendring fra tilleggsdel til hoveddel innenfor en boenhet. ``` -------------------------------- ### K 4 Construction Category Examples Source: https://github.com/taffen/tek-17/blob/main/TEK17.md Examples of construction types that fall under category K 4, involving significant population influx or important societal functions. ```text Tiltak som medfører større tilflytting/personopphold, samt tiltak som gjelder viktige samfunnsfunksjoner ``` ```text bolighus/fritidsboliger med mer enn to boenheter sykehjem og sykehus skole og barnehage idrettshaller utendørs publikumsanlegg nærings- og industribygg ``` -------------------------------- ### Guidance on Entrance Lighting Source: https://github.com/taffen/tek-17/blob/main/TEK17.md Details lighting requirements for entrances in buildings requiring accessible dwelling units or universal design, ensuring visibility against surrounding surfaces with specific luminance contrast. ```text Veiledning til annet ledd bokstav a ``` ```text 1. Belysningsstyrken tilpasses material- og fargebruken slik at inngangspartiet og hovedinngangsdøren blir synlig i forhold til omliggende flater med luminanskontrast minimum 0,4. ``` ```text 2. Lysarmatur må utformes og plasseres slik at lyset ikke blender eller reflekteres på en måte som gir ubehag eller nedsatt syn. ``` -------------------------------- ### Safety Class F2 Examples Source: https://github.com/taffen/tek-17/blob/main/TEK17.md Defines Safety Class F2 for most buildings intended for human occupancy, listing examples such as residences, schools, offices, and industrial buildings. ```text Sikkerhetsklasse F 2 omfatter de fleste byggverk beregnet for personopphold. Byggverk som kan inngå i denne sikkerhetsklassen er ``` bolig, fritidsbolig og campinghytte garasjeanlegg og brakkerigg skole og barnehage kontorbygning industribygg driftsbygning i landbruket som ikke inngår i sikkerhetsklasse F 1 ``` ``` -------------------------------- ### Documentation Phases in Building Projects Source: https://github.com/taffen/tek-17/blob/main/TEK17.md Defines the key phases for which documentation is required: concept (main design), detailed design, and execution. This distinction is particularly relevant for fire safety and energy efficiency in larger projects. ```text konsept (hovedutforming) – dokumentasjon for oppfyllelse av funksjonskrav og underlag som er tilstrekkelig for detaljprosjekteringen detALJPROSJEKTERING – dokumentasjon for oppfyllelse av ytelser og produksjonsunderlag som er tilstrekkelig for utførelsen utførelse - dokumentasjon for at utførte løsninger er i samsvar med produksjonsunderlaget ``` -------------------------------- ### Exclusion of Technical Installations from Storage Area (TEK17 § 12-10) Source: https://github.com/taffen/tek-17/blob/main/TEK17.md Clarifies that areas for technical installations like ventilation and hot water systems cannot be included in the required storage area. ```text Areal til tekniske installasjoner for ventilasjon, varmtvann og lignende kan ikke inngå i oppbevaringsarealet. ``` -------------------------------- ### Environmental Program and Follow-up Plan Source: https://github.com/taffen/tek-17/blob/main/TEK17.md Suggests creating an environmental program and an environmental follow-up plan to document and manage environmental goals and measures. ```text For å begrense belastningen på ytre miljø, er det viktig å vurdere miljøpåvirkningen ved oppføring og drift av bygget allerede tidlig i prosessen. På bakgrunn av denne vurderingen utarbeides miljømål. Miljømål og miljøtiltak må følges opp jevnlig i prosjektet, på lik linje med funksjonelle, tekniske og økonomiske hensyn. ``` -------------------------------- ### Marking of Fire Safety Installations Source: https://github.com/taffen/tek-17/blob/main/TEK17.md Emphasizes the requirement for clear marking of fire safety installations that are significant for rescue and firefighting operations. This ensures that emergency and maintenance personnel have necessary information. ```text Branntekniske installasjoner som har betydning for rednings- og slokkeinnsatsen skal være tydelig merket. ``` -------------------------------- ### Safety Class F1 Examples Source: https://github.com/taffen/tek-17/blob/main/TEK17.md Defines Safety Class F1 for structures with low occupancy and minor consequences, listing examples like garages and storage buildings with minimal human presence. ```text Sikkerhetsklasse F 1 omfatter byggverk med lite personopphold og små økonomiske eller andre samfunnsmessige konsekvenser. Byggverk som kan inngå i denne sikkerhetsklassen er ``` garasje lagerbygning med lite personopphold ``` ``` -------------------------------- ### Ledesystem and Emergency Lighting Standards Source: https://github.com/taffen/tek-17/blob/main/TEK17.md References NS 3926-1:2017 for the design and execution of guidance systems and NS-EN 1838 for emergency lighting, noting their combined use for effective evacuation. ```text Størrelsen på brannceller og persontall legges til grunn for valg av type ledesystem. For prosjektering og utførelse av ledesystem vises til NS 3926-1:2017. Forskrift om utforming og innretning av arbeidsplasser og arbeidslokaler (arbeidsplassforskriften), stiller krav om nødbelysning der arbeidstakere kan bli utsatt for fare ved svikt i den kunstige belysningen. Denne forskriften stiller også krav om at rømningsveier og nødutganger skal være utstyrt med nødlys som er tilstrekkelig til å dekke behovet i tilfeller med svikt i den ordinære belysningen. For prosjektering og utførelse av nødbelysning vises til NS-EN 1838. Ved prosjektering av byggverk der arbeidsplassforskriften gjelder, kan kravene i de to forskriftene ses i sammenheng. Ledesystem og nødbelysning kan prosjekteres slik at disse installasjonene samlet sett gir de beste forutsetningene for rask og effektiv rømning. ``` -------------------------------- ### Reducing Energy Use with Central Control Systems Source: https://github.com/taffen/tek-17/blob/main/TEK17.md This snippet suggests using a central control system (SD-anlegg) to reduce energy consumption in heating and cooling installations. It highlights the potential for optimal control of technical installations. ```text Energibruken kan reduseres, for eksempel gjennom bruk av system for sentral driftskontroll (SD-anlegg). Dette kan gi optimal styring av tekniske installasjoner. ``` -------------------------------- ### Safety Class F3 Examples Source: https://github.com/taffen/tek-17/blob/main/TEK17.md Defines Safety Class F3 for structures serving vulnerable societal functions or posing pollution risks if flooded, listing examples like nursing homes, hospitals, and waste disposal sites. ```text Sikkerhetsklasse F 3 omfatter byggverk for sårbare samfunnsfunksjoner og byggverk der oversvømmelse kan gi stor forurensning på omgivelsene. Byggverk som kan inngå i denne sikkerhetsklassen er ``` Byggverk for særlig sårbare grupper av befolkningen, for eksempel sykehjem og lignende. Byggverk som skal fungere i lokale beredskapssituasjoner, for eksempel sykehus, brannstasjon, politistasjon, sivilforsvarsanlegg og infrastruktur av stor samfunnsmessig betydning. For byggverk som har regional eller nasjonal betydning i beredskapssituasjoner gjelder første ledd. Avfallsdeponier der oversvømmelse kan gi forurensningsfare. ``` ``` -------------------------------- ### Leakage Prevention in Chemical Medium Installations Source: https://github.com/taffen/tek-17/blob/main/TEK17.md This snippet discusses methods for preventing leaks in installations handling chemical media, specifically mentioning soldered or welded connections as effective solutions. It applies to general leakage prevention requirements. ```text I installasjoner for kjemiske medier vil lodde- eller sveiseforbindelser kunne sikre mot lekkasjer. ``` -------------------------------- ### Ledesystem Scenarios Source: https://github.com/taffen/tek-17/blob/main/TEK17.md Defines scenarios where a guidance system (ledesystem) should be usable, including evacuation during a fire alarm without visible fire/smoke, power failure, or unforeseen events. ```text Ledesystemet skal kunne benyttes av de som oppholder seg i byggverket i følgende enkeltscenarier eller i en kombinasjon av disse: a. Ved evakuering som følge av en utløst brannalarm der det ikke er tegn til brann- eller røykutvikling i bygget b. Ved rømning og evakuering ved bortfall av kunstig belysning c. Ved rømning og evakuering som følge av uforutsette hendelser som brann – og røykutvikling ``` -------------------------------- ### Specifying Pre-accepted Performance Levels Source: https://github.com/taffen/tek-17/blob/main/TEK17.md Highlights the need to specify assumptions and chosen performance levels when using pre-accepted values, as simply confirming their use is insufficient. ```text Siden det på mange områder er mulig å velge ulike preaksepterte ytelser, er det nødvendig å spesifisere hvilke forutsetninger og ytelser som legges til grunn. Det er altså ikke tilstrekkelig kun med en bekreftelse på at de preaksepterte ytelsene er fulgt. ``` -------------------------------- ### Guidance on Marking Fire Safety Installations Source: https://github.com/taffen/tek-17/blob/main/TEK17.md Provides guidance on the purpose of marking fire safety installations. The aim is to give fire and rescue personnel essential information for effective task execution and to provide clear information for maintenance personnel. ```text Formålet med merking er å gi brann- og redningspersonell nødvendig informasjon for å løse sine oppgaver på en effektiv måte. Det er dessuten vesentlig at kvalifisert personell som utfører ettersyn, service og vedlikehold av slike installasjoner, får god og lettfattelig informasjon om det enkelte system og sammenhengen mellom systemene. ``` -------------------------------- ### Guidance on Meeting Functional Requirements Source: https://github.com/taffen/tek-17/blob/main/TEK17.md Explains how to document compliance with functional requirements when specific performance values are not provided in the regulation. ```text På noen områder er funksjonskrav fortolket og gitt som ytelseskrav i forskriften. Dette gjelder for eksempel krav knyttet til tilgjengelig boenhet. ``` -------------------------------- ### Environmental Impact Examples - Noise Source: https://github.com/taffen/tek-17/blob/main/TEK17.md Highlights unacceptable noise levels in outdoor recreational areas as an environmental impact. ```text Støy Uakseptable lydforhold på uteoppholdsareal ``` -------------------------------- ### Placeholder Text 2 Source: https://github.com/taffen/tek-17/blob/main/TEK17.md This is a placeholder text snippet. ```text Bestemmelsen vil gjelde for løfteinnretninger som definert i § 16-1. ```